How does automated balancing of the battery and battery maintenance work?

Answer:

Most batteries on the market need to activate certain functions occasionally to ensure proper operation and longevity. To maintain proper operation and longevity over time, batteries need to be balanced periodically.


Ferroamp now fully automates this process to ensure the performance of our customers. LFP batteries need to balance so that the battery cells in the system are as equal as possible to achieve optimal performance over time. EnergyHub performs this by responding to commands from the battery's BMS, which indicates when balancing needs to be done.


Balancing occurs during the night between 23:00 and 04:00 to minimize disruption, It usually finishes within one or two hours, but in exceptional cases can take up to 30 hours. Our ambition is to eventually offer users the ability to determine when balancing occurs. Note that this is for software version 5.9.0.


This is what applies to our different types of batteries:


  • Batteries from Pylontech
    • Balancing occurs when needed but with maximum 3 months interval. It involves charging up the battery. Even if you have set charging restrictions, the battery will charge. When the balancing is completed, it will return to previous settings.


  • Batteries from PSM 
    • Cycling occurs about once a month by performing a full charging cycle, which means the battery cycles from 100 to 0% and 0 to 100%. Even if you have set charging restrictions, the battery will charge fully. When the balancing is completed, it will return to previous settings.


If for any reason the balancing is interrupted or not completed in time, it will repeat the procedure the next night.


We constantly want to improve the content in the Knowledge Database and would appreciate it if you give feedback on our articles. Does all the information exist, is there anything that needs to be clarified or is there any information that is missing that would help installing or using the EnergyHub system in general? You can give us feedback by choosing if the article was helpful or not in the options below. 

If you need to get in contact with Ferroamp's Technical Support or if you have any questions about the system, you can do so by creating a ticket 
here



Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article